Operating Conditions
Name | Unit | Specification | |
Model | AD-MFI-A | ||
Membrane Area | m² | 10.7/35 | |
Material | Hollow Fiber Membrane | -- | PVDF+PET |
Sealant Resin | -- | Polyurethane Resin | |
Support Rod | -- | SUS304/316 | |
Membrane Box Material | -- | ABS | |
Membrane Fiber Inner and Outer Diameter | mm | 1.0/2.0 | |
Membrane Fiber Pore Size | micrometer | 0.1 | |
Water Turbidity | NTU | <1 | |
Size | mm | 680*30*1500/1250*30*2000 | |
Effective Length of Membrane Fiber | mm | 1360/1860 |
[Note]: (1) Other specifications and sizes of membrane products can be customized according to user needs. (2) The arrangement of membrane fibers can be customized for packaging.
Name | Unit | Range |
Working Temperature | ℃ | 6-35 |
Operating pH | -- | 6-9 |
Acid-Base Resistance | -- | pH2-12 |
Design Flux | L/m² ·h | 15-30 |
Operating Mode | Negative Pressure Suction | |
Maximum Transmembrane Pressure Difference | kPa | 45 |
Gas-Water Ratio | (3-8):1 | |
Influent Animal and Vegetable Oil | mg/L | <50 |
Influent Mineral Oil | mg/L | <3 |
Recommended Sludge Concentration (MLSS) | mg/L | 5000-12000 |
[Note]: The specific operating mode should be set according to the characteristics of the influent water quality and operating conditions.