Product Specification

Membrane Element ModelAverage Permeability
GPD(m³/d)
Average Desalination Rate %Membrane Area ft²(m²)Feed Water Channel (mil)
AD-RO-ULP40402600(9.8)99.5 85(8)28 
AD-RO-ULP8040-40010500(39.7)99.5 400(37)34 
AD-RO-ULP8040-44011500(43.5)99.5 440(41)28 
[ Note ]: The average permeability of a single element may vary, but the range of variation does not exceed ±15%.

Testing Conditions

Operating Pressure…………………………………150psi (1.03MPa)
Temperature………………………………………77 ℉ (25℃)
Concentration………………………………………1500mg/L NaCl
Single Membrane Element Recovery Rate………………………15%
pH…………………………………………7.5-8.0

Product Size

ElementBCD
4040 40.0 (1016mm) 1.05  (26.7mm)0.75(19mm)3.9  (99mm)

 

ElementBC
804040.0 (1016mm)1.125 (29mm)7.9 (201mm)

Operating Limits

Maximum Operating Pressure……………………………600psi(4.1MPa)
Maximum Inlet Temperature……………………………113° F(45℃ )
Maximum Inlet SDI……………………………5
Inlet Free Chlorine Concentration…………………………< 0.1ppm
pH Range of Inlet Water During Continuous Operation………………2-11
pH Range of Inlet Water During Chemical Cleaning………………1-13
Maximum Pressure Loss of a Single Membrane Element………………15psi(0.10MPa)

Precautions

① The product water from the system should be discarded one hour before the first startup;

② During startup and shutdown, excessive fluctuations in flow and pressure pose a risk of membrane element rupture. The system should gradually increase/decrease pressure and flow during startup and shutdown operations, with a pressure rise/fall rate ≤ 0.07MPa/s.

③ The inlet SDI value must be below 5.0.

④ It is strictly prohibited for grease to enter the reverse osmosis system.

⑤ Higher pressure on the product side than on the feed water side can cause physical damage to the membrane, so back pressure on the product side of the membrane element must be avoided at all times.

General Information

① Each membrane element is equipped with a concentrate sealing ring, a connection adapter, and corresponding O-rings at the time of shipment; specific contents are subject to the actual product;

② Once the element is wetted, it should always be kept moist;

③ When the system is out of service for a long time, the membrane element should be immersed in a protective liquid to prevent microbial growth. The standard preservation liquid contains 1.0% (weight) sodium bisulfite (food grade) and 1.0% (weight) sodium citrate (food grade);

④ Users should avoid using any chemical agents that may affect the membrane element. If such chemical agents are used, Jiangsu Aidemans Technology Co., Ltd. will not assume warranty responsibility.

⑤ Due to the inability to control the user's methods and conditions of use, Aidemans Company does not assume responsibility for the consequences caused by the use of the information and data in this sample, nor for the guarantee of the safety and applicability of the product, whether used alone or in conjunction with other products. Users are advised to conduct tests to determine its safety and whether it is suitable for their specific purposes.

⑥ Due to technical improvements and product updates, technical data may change at any time without prior notice.

Keywords

Send Query

Please leave your email and our professionals will contact you as soon as possible!

Reverse Osmosis ULP
Reverse Osmosis ULP
Reverse Osmosis ULP
+
  • Reverse Osmosis ULP
  • Reverse Osmosis ULP
  • Reverse Osmosis ULP

Reverse Osmosis ULP

The ULP series ultra-low pressure reverse osmosis industrial membrane elements are products developed by the company for desalination of surface/groundwater using aromatic polyamide composite membranes. They feature the ability to achieve a high water production rate at low operating pressures, significantly reducing system operating costs while lowering investment costs for pumps, pipelines, containers, and other equipment, thereby improving economic benefits. They are suitable for desalination treatment of water sources such as surface water, groundwater, tap water, and municipal water with a salinity of approximately below 2000ppm.


Related Products